MS® Syringe filters are purpose-built with features
designed to bring the highest levels of performance and purity to
your research. We incorporate a variety of membranes to offer separation
and purification solutions for the majority of your laboratory needs.
Syringe filter with prefilter prevents blockage and bursting of
the actual membrane for the fine filtration. In addition, there
several type of Syringe filter with prefilters are available, such
as Nylon Syringe Filter with PP prefilter, PTFE Syringe Filter with
PP prefilter, PVDF Syringe Filter with PP prefilter, Nylon Syringe
Filter with GF prefilter, PTFE Syringe Filter with GF prefilter
as well as PVDF Syringe Filter with GF prefilter.
| Items | Application |
| Nylon Syringe Filter with PP prefilter | Aqueous or organic sample prep, HPLC, GC, or dissolution sample analysis, high retention ability |
| PTFE Syringe Filter with PP prefilter | Aggressive solvents, filter organic-based HPLC samples, degassing solvents, aerosol sampling, venting application, vacuum pump line protection, high retention ability |
| PVDF Syringe Filter with PP prefilter | Aggressive and non-aggressive solvent- based mobile phase, low level UV-absorbing Extractable, protection column against particulate, high retention ability |
| PES Syringe Filter with PP Prefilter | Low level IC interference by ICP analysis Hydrophilic membrane provides excellent flow rates and low binding coefficients |
| Nylon Syringe Filter with GF prefilter | Aqueous or organic sample prep, HPLC, GC, or dissolution sample analysis, higher absorption capacity for contamination |
| PTFE Syringe Filter with GF prefilter | Aggressive solvents, filter organic-based HPLC samples, degassing solvents, aerosol sampling, venting application, vacuum pump line protection, higher absorption capacity for contamination |
| PVDF Syringe Filter with GF prefilter | Aggressive and non-aggressive solvent- based mobile phase, low level UV-absorbing Extractable, protection column against particulate, higher absorption capacity for contamination |
| PES Syringe Filter with GF Prefilter | Low level IC interference by ICP analysis Hydrophilic membrane provides excellent flow rates and low binding coefficients; low affinity for binding drugs; ideal dissolution testing procedures |
| Items | Pore Size | Diameter | Package | Prefilter | |
| Material | Pore Size | ||||
| Nylon Syringe Filter with PP prefilter | 0.22/0.45 um | 13mm,25mm | No sterile | Polypropylene | 1.0 um |
| PTFE Syringe Filter with PP prefilter | 0.22/0.45 um | 13mm,25mm | No sterile | Polypropylene | 1.0 um |
| PVDF Syringe Filter with PP prefilter | 0.22/0.45 um | 13mm,25mm | No sterile | Polypropylene | 1.0 um |
| Nylon Syringe Filter with GF prefilter | 0.22/0.45 um | 13mm,25mm | No sterile | Glass Fiber | 1.0 um |
| PTFE Syringe Filter with GF prefilter | 0.22/0.45 um | 13mm,25mm | No sterile | Glass Fiber | 1.0 um |
| PVDF Syringe Filter with GF prefilter | 0.22/0.45 um | 13mm,25mm | No sterile | Glass Fiber | 1.0 um |
| Item# | Description | Pcs per box | Online Price(US$) | Order |
| SFCA025022NG | Nonsterile CA Syringe Filter with Glass Fiber Prefilter, Pore:0.22(μm), Diameter:25(mm) | Ask for Quotes | ||
| SFCA013045NG | Nonsterile CA Syringe Filter, Pore:0.45(μm), Diameter:13(mm), with GF Pre-filter | Ask for Quotes | ||
| SFCA025045NG | Nonsterile CA Syringe Filter, Pore:0.45(μm), Diameter:25(mm), GF prefilter | Ask for Quotes | ||
| SFNY013022NG | Nonsterile Nylon Syringe Filters,Pore: 0.22(μm), Diameter: 13(mm), GF Prefilter | 500 | 415.6000 | Add to cart |
| SFNY013045NG | Nonsterile Nylon Syringe Filters, Pore:0.45(μm), Diameter:13(mm), GF Prefilter | 500 | 415.6000 | Add to cart |
| SFNY025045NG | Nonsterile Nylon Syringe Filters, Pore:0.45(μm), Diameter:25(mm), GF Prefilter | 200 | 230.2700 | Add to cart |
| SFPES013022NG | Nonsterile PES Syringe Filters, Pore:0.22(μm), Diameter:13(mm), GF prefilter | 500 | 415.6000 | Add to cart |
| SFPES025022NG | Nonsterile PES Syringe Filters, Pore:0.22(μm), Diameter:25(mm), GF Prefilter | 200 | 268.9700 | Add to cart |
| SFPES013045NG | Nonsterile PES Syringe Filters, Pore:0.45(μm),Diameter: 13(mm), GF Prefilter | 500 | 415.6000 | Add to cart |
| SFPES025045NG | Nonsterile PES Syringe Filters, Pore:0.45(μm), Diameter:25(mm), GF Prefilter | 200 | 268.9700 | Add to cart |
| SFPTFE013022NG | Nonsterile PTFE Syringe Filters, Pore:0.22(μm), Diameter:13(mm), GF Prefilter | 500 | 394.7500 | Add to cart |
| SFPTFE013045NG | Nonsterile PTFE Syringe Filters, Pore:0.45(μm), Diameter:13(mm), GF Prefilter | 500 | 394.7500 | Add to cart |
| SFPTFE025045NG | Nonsterile PTFE Syringe Filters, Pore:0.45(μm),Diameter: 25(mm), GF Prefilter | 200 | 268.9700 | Add to cart |
| SFPVDF025022NG | Nonsterile PVDF Syringe Filter, Pore:0.22(μm),Diameter: 25(mm), GF Prefilter | 200 | 268.9700 | Add to cart |
| SFPVDF050022NG | Nonsterile PVDF Syringe Filter, Pore:0.22(μm), Diameter:50(mm), GF Prefilter | Ask for Quotes | ||
| SFPVDF050022NP | Nonsterile PVDF Syringe Filter, Pore:0.22(μm), Diameter:50(mm), PP Prefilter | Ask for Quotes | ||
| SFPVDF013045NG | Nonsterile PVDF Syringe Filter,Pore: 0.45(μm),Diameter: 13(mm), GF Prefilter | 500 | 394.7500 | Add to cart |
| SFPVDF025045NG | Nonsterile PVDF Syringe Filters, Pore:0.45(μm), Diameter:25(mm), GF Prefilter | 200 | 268.9700 | Add to cart |
| SFPVDF050045NG | Nonsterile PVDF Syringe Filter, Pore:0.45(μm), Diameter:50(mm), GF Prefilter | Ask for Quotes | ||
| SFPVDF050045NP | Nonsterile PVDF Syringe Filter, Pore:0.45(μm), Diameter:50(mm), PP Prefilter | Ask for Quotes | ||