MS Hydrophobic PES Membrane
Online Ordering
| Specs | Number | Description | Price |
|---|
Related Documents
![]() |
| Hydrophobic PES Membrane Datasheet |
Features
Hydrophobic PES membranes are more breathable than PVDF membranes, and their inherent strong gamma tolerance is more stable than PTFE membranes, which can remove polluting particles and microorganisms in gases, and are mainly used for sterilization and filtration of air and gases, which can effectively keep the system sterile and breathable.
- Excellent hydrophobicity
- High air velocity
- Gamma irradiation, alkaline rinse sterilization, and autoclave resistance
- Reliable retention of particles, aerosols and microorganisms
- High heat and mechanical resistance
- Passed 107 CFU/cm2 Brevundimonas diminuta (ATCC 19146) retention test
- No release of insoluble particulate matter to meet USP 788 requirements; Low dissolution and precipitation, in accordance with USP 661 requirements
- Biosafety meets USP 87 < in vitro cytotoxic > and USP 88 Class VI < implantable medical raw material > standards
Applications
- Ventilation caps
- Sterilization ventilation of cell culture flasks and bottles, bioreactors, and fermenters
- Liquid blocking device
- Aseptic filling air filtration
- Ventilation filters in medical devices
Technical Parameters
|
Membrane Material |
PES |
|
Wetting Performance |
Hydrophobic |
|
Pore Size |
0.22μm |
|
Support |
None |
|
Structure |
Asymmetry |
|
Thickness |
100-130μm |
|
Width |
254mm/260mm |
|
The water Breaks Through the Pressure |
>230kPa |
|
Air Flow Rate(L/min/cm²@7kPa) |
0.2-0.3 |
|
Bacterial Retention |
>7LRV(Brevundimonas diminuta) |
|
Sterilization |
Autoclaving, ethylene oxide, Gamma |
|
Membrane Testing Reports Available |
Pore Size Analysis Report Contact Angle Test Tensile Strength Test Report |
FAQ
Basic Characteristics
1.What are the main advantages of PES hydrophobic membranes compared to PTFE (polytetrafluoroethylene) hydrophobic membranes?
Compared to PTFE, PES membranes are completely fluorine-free and comply with PFAS regulations. Additionally, PES membranes exhibit superior stability under gamma radiation sterilization.
2.What is the “hydrophobicity” rating of your company’s PES hydrophobic membranes? What is the maximum water pressure they can withstand without leaking?
The water contact angle of our PES hydrophobic membranes typically ranges between 100° and 120°. The specific water pressure resistance (static or inlet pressure) depends on the membrane thickness and pore size:
- Standard 0.22μm pore size: Water pressure resistance ≥ 2.4 MPa
- Standard 0.45 μm pore size: Water pressure resistance ≥ 1.5 MPa
If specific pressure resistance values are required, we offer custom membranes with higher water pressure resistance.
Applications and Selection
1.Can this membrane be used for filtering organic solvents such as alcohol and IPA(isopropyl alcohol)?
Yes. PES material inherently possesses excellent resistance to organic solvents. However, please note that low-surface-tension liquids (such as alcohol) can easily penetrate hydrophobic membranes under pressure. If your application involves filtering organic solvents, we recommend selecting our “Solvent-Resistant” series (with enhanced cross-linking treatment) or reducing the operating pressure differential.
2.Does the product support gamma ray sterilization or autoclave sterilization?
Yes. Our PES hydrophobic membranes have been validated to withstand 50 kGy gamma irradiation sterilization as well as autoclave sterilization at 134°C for 30 minutes over 20 cycles. The decline in the membrane’s hydrophobicity (contact angle) before and after sterilization is controlled within 5%, ensuring that the sterile barrier function of medical devices remains intact.
Process and Customization
1.Are your films supplied in rolls or sheets? Do you support backing lamination?
We offer rolls with a standard width of 260 mm. For narrower widths, we expect to provide more customized width options once our slitting machine becomes operational in June 2026. To enhance stiffness for use in automated assembly lines, we support thermal lamination of PES hydrophobic film with PET, PE, or PP non-woven backing, facilitating ultrasonic welding or heat sealing for our customers.