MedCap-UTC PTFEG Series PTFE Capsule Filter with Strong Chemical Resistance

Request a Quote
Item No Product Name Description
C150H4PTFEG020 UTC Capsule filter normal size: 2.5"*6", filtration media: Hydrophobic PTFE, pore size: 0.20μm, inlet: 1/2" Hosebarb, outlet: 1/2" Hosebarb Request a Quote
C150H4PTFEG045 UTC Capsule filter normal size: 2.5"*6", filtration media: Hydrophobic PTFE, pore size: 0.45μm, inlet: 1/2" Hosebarb, outlet: 1/2" Hosebarb Request a Quote
C150H4PTFEG120 UTC Capsule filter normal size: 2.5"*6", filtration media: Hydrophobic PTFE, pore size: 1.2μm, inlet: 1/2" Hosebarb, outlet: 1/2" Hosebarb Request a Quote
C150N2PTFEG020 UTC Capsule filter normal size: 2.5"*6", filtration media: Hydrophobic PTFE, pore size: 0.20μm, inlet: 1/4" MNPT, outlet: 1/4" MNPT Request a Quote
C150N2PTFEG045 UTC Capsule filter normal size: 2.5"*6", filtration media: Hydrophobic PTFE, pore size: 0.45μm, inlet: 1/4" MNPT, outlet: 1/4" MNPT Request a Quote
C150TCAPTFEG020 UTC Capsule filter normal size: 2.5"*6", filtration media: Hydrophobic PTFE, pore size: 0.20μm, inlet: 1 1/2" Tri-clamp, outlet: 1 1/2" Tri-clamp Request a Quote
C150TCAPTFEG045 UTC Capsule filter normal size: 2.5"*6", filtration media: Hydrophobic PTFE, pore size: 0.45μm, inlet: 1 1/2" Tri-clamp, outlet: 1 1/2" Tri-clamp Request a Quote
C300H4PTFEG020 UTC Capsule filter normal size: 2.5"*8", filtration media: Hydrophobic PTFE, pore size: 0.20μm, inlet: 1/2" Hosebarb, outlet: 1/2" Hosebarb Request a Quote
C300H4PTFEG045 UTC Capsule filter normal size: 2.5"*8", filtration media: Hydrophobic PTFE, pore size: 0.45μm, inlet: 1/2" Hosebarb, outlet: 1/2" Hosebarb Request a Quote
C300N4PTFEG010 UTC Capsule filter normal size: 2.5"*8", filtration media: PTFEG, pore size: 010μm, inlet: 1/2" MNPT, outlet: 1/2" MNPT Request a Quote

Description

MedCap-UTC PTFEG series capsule filter is made of high porosity hydrophobic PTFE membrane, which has a wide range of chemical tolerance and can provide stable and reliable filtration performance of sterilization and particle removal. Its removal ratings of typical bacteria in the industry have been verified by batches, which can effectively reduce the level of microbial load in liquid filtrate and gas, and is especially suitable for the filtration of various low surface tension chemicals and gases.

Features

  • High porosity PTFE membrane

  • Prefiltration of gas sterilization

  • Broad chemical tolerance

  • High particle retention efficiency

  • Various cages and connections are available

Applications

  • Sterilization of bio-fermentation gas

  • Filtration of aseptic packaging gas

  • Sterilization of food fermentation gas

  • Sterilizing filtration of respirator 

  • Filtration of chemical sovents

Technical Parameters

Materials of Construction

Filter Membrane

PTFE

Support/Drainage

PP

Core/Cage/End Cap

PP

Capsule Shell

PP

Removal Ratings

0.10μm、0.20μm、0.45μm、1.0μm、5.0μm、10.0μm

Filtration Area

C80/ C150 / C300 / C610 / C620

450-840cm2/ 1200-1400cm2/2400-2800cm2/ 5500-6000cm2/11000-12000cm2

Operating Conditions

Maximum Operating Differential Pressure

0.5MPa@25℃

0.1MPa@80℃

Maximum Operating Temperature

80℃

Sterilization Method

Autoclave steam sterilization:30min@121℃

Hot water disinfection:30min@90℃

Biological Safety

Bio-compatibility

Meet USP <87> in vitro Cytotoxicity Test

Meet the criteria of the USP <88> Biological Reactivity Test for Class VI-121°C plastics

Endotoxins

<0.25EU/mL

Ordering Information

Capsule Filter Size

Inlet/Outlet

PTFEG

Removal Ratings

C80

C150

C300

C610

C620

N2  1/4"NPT
N3  3/8"NPT
N4  1/2"NPT
H1  1/8"Hosebarb**
H2  1/4"Hosebarb
H3  3/8"Hosebarb
H4  1/2"Hosebarb*
HS  1/4"-1/2" Steeped Hosebarb
HC  1/4"-3/8" Steeped Hosebarb
TCA  1 1/2" Tri-clamp
TCB  1/2" Tri-clamp
TCC  1" Tri-clamp

* For C610/C620 Size

** Not available for C80

010 0.10μm

020 0.20μm

045 0.45μm

100 1.0μm

500 5.0μm

H10 10.0μm