Item No Product Name Description
CRGF0050204S ProtecPure Series Cartridge Pore Size:0.20μm, length:5inch, Adapter Type:222/Fin with SS insert, Sealing:Silicone, Core:Polypropylene Request a Quote
CRGF0100206E ProtecPure Series Cartridge Pore Size:0.20μm, length:10inch, Adapter Type:226/Fin, Sealing:EPDM, Core:Polypropylene Request a Quote
CRGF0101006F ProtecPure Series Cartridge Pore Size:1.0μm, length:10inch, Adapter Type:226/Fin, Sealing:FKM, Core:Polypropylene Request a Quote
CRGF0201006N ProtecPure Series Cartridge Pore Size:1.0μm, length:20inch, Adapter Type:226/Fin, Sealing:NBR, Core:Polypropylene Request a Quote
CRGF0202000PV ProtecPure Series Cartridge Pore Size:2.0μm, length:20inch, Adapter Type:DOE, Sealing:FEP Encapsulated FKM, Core:Polypropylene Request a Quote
CRGF0300456S ProtecPure Series Cartridge Pore Size:0.45μm, length:30inch, Adapter Type:226/Fin, Sealing:Silicone, Core:Polypropylene Request a Quote
CRGF0301005E ProtecPure Series Cartridge Pore Size:1.0μm, length:30inch, Adapter Type:226/Fin with SS insert, Sealing:EPDM, Core:Polypropylene Request a Quote
CRGF0400450N ProtecPure Series Cartridge Pore Size:0.45μm, length:40inch, Adapter Type:DOE, Sealing:NBR, Core:Polypropylene Request a Quote
CRGF0401006S ProtecPure Series Cartridge Pore Size:1.0μm, length:40inch, Adapter Type:226/Fin, Sealing:Silicone, Core:Polypropylene Request a Quote
CRGFJ20300ME ProtecPure Series Cartridge Pore Size:0.3μm, Length:2inch, 116 Internal O-ring, EPDM Request a Quote

Description

ProtecPure GF filters are designed for providing excellent protection to downstream filters. Glass microfiber layer has a unique three dimensional structure. It can provide high dirt holding capacity and high removal effect. GF filters are suitable for retaining colloidal matter from high burden and high viscosity fluid.

Applications

  • Remove particles from viscous liquids

  • Lipids and colloids removal

  • Bio-burden removal

  • Clarify product to extend the lifetime of membrane filters

Product Assurance

  • ASTM F838-83

  • FDA 21 CFR 177

  • ISO 10993-Part 1, 5

  • EN 285:2015

  • Regulation (EC) No 1935/2004

Technical Parameters

Materials of Construction

Filter Membrane

Glass Fiber

Support

PP

Cage/End Cap

PP

Core

PP

Adaptor

PP

O-rings

Silicone/EPDM

Filter Dimensions

Outer Diameter

68.5mm

Inner Diameter

33.0mm

Filtration Area

0.8μm

≥0.35m²

1μm

≥0.41m²

3~10μm

≥0.44m²

Operating Conditions

Maximum Operating Temperature

1.9 bar @ 82℃

Maximum Differential Pressure (forward)

5.2 bar @ 25℃

Maximum Differential Pressure (reverse)

2.1 bar @ 25℃

Recommended Change-out Differential Pressure

2.4 bar

Sterilization Conditions

Hot Water Disinfection

85℃, 60min

Autoclave

124℃, 30min

Steam In-place

124℃, 30min

Ordering Information

Filter Media

Length

Pore Size

Adaptor

Seal Material

Core

CRGF:

Glass Fiber

005=5inches

010=10inches

020=20inches

030=30inches

040=40inches

080=0.8μm

100=1.0μm

300=3.0μm

500=5.0μm

1000=10.0μm

0=DOE

2=222/Flat

3=222/Fin

5=226/Fin with SS insert

6=226/Fin

7=226/Flat

S=Silicone

E=EPDM

Blank=PP

S=Stainless Steel

P=Polysulfone