PolymidPure Series Nylon66 Pleated Filter Cartridge with High Strength and High Temperature Resistance
Request a QuoteItem No | Product Name | Description | |
---|---|---|---|
CRNY0050200S | PolymidPure Series Cartridge | Medium: Nylon 6,6, Pore Size: 0.20μm, Length: 5inch, OD: 69mm, Adapter Type: DOE, Sealing: Silicone | Request a Quote |
CRNY0100103F | PolymidPure Series Cartridge | Medium: Nylon 6,6, Pore Size: 0.10μm, Length: 10inch, OD: 69mm, Adapter Type: 222/Fin, Sealing: FKM | Request a Quote |
CRNY0100200E | PolymidPure Series Cartridge | Medium: Nylon 6,6, Pore Size: 0.20μm, Length: 10inch, OD: 69mm, Adapter Type: DOE, Sealing: EPDM | Request a Quote |
CRNY01N0100S | PolymidPure Series Cartridge | Medium: Nylon 6,6, Pore Size: 0.10μm, Length: 9.75inch, OD: 69mm, Adapter Type: DOE, Sealing: Silicone | Request a Quote |
CRNY0200106E | PolymidPure Series Cartridge | Medium: Nylon 6,6, Pore Size: 0.10μm, Length: 20inch, OD: 69mm, Adapter Type: 226/Fin, Sealing: EPDM | Request a Quote |
CRNY0200206N | PolymidPure Series Cartridge | Medium: Nylon 6,6, Pore Size: 0.20μm, Length: 20inch, OD: 69mm, Adapter Type: 226/Fin, Sealing: NBR | Request a Quote |
CRNY0300203E | PolymidPure Series Cartridge | Medium: Nylon 6,6, Pore Size: 0.20μm, Length: 30inch, OD: 69mm, Adapter Type: 222/Fin, Sealing: EPDM | Request a Quote |
CRNY0300206S | PolymidPure Series Cartridge | Medium: Nylon 6, 6, Pore Size: 0.20μm, Length: 30inch, OD: 69mm, Adapter Type: 226/Fin, Sealing: Silicone | Request a Quote |
CRNY0400103F | PolymidPure Series Cartridge | Medium: Nylon 6,6, Pore Size: 0.10μm, Length: 40inch, OD: 69mm, Adapter Type: 222/Fin, Sealing: FKM | Request a Quote |
CRNY0401206S | PolymidPure Series Cartridge | Medium: Nylon 6,6, Pore Size:1.20μm, Length: 40inch, OD: 69mm, Adapter Type: 226/Fin, Sealing: Silicone | Request a Quote |
Description
PolymidPure nylon 6,6 pleated filter cartridge uses a controlled porosity and naturally hydrophilic nylon 6,6 membrane, which does not contain any wetting agents, and has excellent chemical compatibility and mechanical strength. After special cleaning steps, the filter membrane has low precipitation and no shedding. It can be widely used in the filtration of strong alkali, weak acid and organic solvents. High quality all-polypropylene components and high strength nylon 6,6 membrane with polyester support layer have excellent heat and pressure resistance and meet the requirements of most applications. PolymidPure can provide sterile-grade filter cartridges with double layer 0.2μm membrane and validation guide that meets regulatory requirements is available.
-
Reliability
Raw materials procurement, product design, production and storage, all operations follow ISO 9001 quality management system. This product is manufactured and packaged in a cleanroom to ensure product cleanliness. Each filter cartridge will undergo a separate integrity test.
-
Economy
The optimized structure of filter cartridges maximize the filtration area to achieve higher flow rate, longer service life and economy.
-
Compatibility
PolymidPure pleated filter cartridge is hot melt welded, and does not contain any adhesive. This product uses naturally hydrophilic nylon 6,6 and food contact grade polypropylene components, which has broad chemical compatibility and can ensure low precipitation in high-temperature environments.
-
Regulatory Compliance
ASTM D6394 SP0112
FDA 21 CFR 177.1655
ISO 10993-Part 1, 5
EN 285:2006+A2:2009.
Regulation (EC) No 1935/2004
Features
-
Naturally hydrophilic, easy to wet
-
Extensive chemical compatibility, resistant to organic solvents
-
Good integrity to ensure the filter sterilizing-grade particle retention efficiency
-
Low pressure drop, high flux, long service life
Applications
-
Sterilizing filtration of sterile APIs, antibiotic solutions, etc.
-
Filtration of alcohol, soft drinks, pure water, etc.
-
Filtration of high- purity chemicals and organic solvents
-
Sterilizing filtration of physiological saline and reagent water
-
Sterilizing filtration of SVP and LVP
Product Assurance
-
ISO 9001:2015 quality management system
-
100% integrity test
-
Filter cartridge is fully traceable
-
All materials comply with relevant requirements of CFR21
-
Bacteria (Pseudomonas diminuta) Liquid Challenge Test TR≥1011
-
Retention efficiency for Monodisperse PSL particles≥99.99%
Technical Parameters
Materials of Construction |
Filter Membrane |
Nylon66 |
Support/Drainage |
PP |
|
Cage/End Cap |
PP |
|
Core |
PP/316L Stainless Steel |
|
Adaptor |
PP/PP+Stainless Steel |
|
O-rings |
S/E/N/F |
|
Sealed by hot-melt welding, no adhesive |
||
Filter Dimensions
|
Outer Diameter |
69mm |
Inner Diameter |
33mm |
|
Length |
5-40inches |
|
Filtration Area |
≥0.33m² (5inches) ≥0.62m²/10inches |
|
Operating Conditions |
Maximum Differential Pressure (forward) |
5.2 bar @ 25℃,1.9 bar @ 82℃ |
Maximum Differential Pressure (reverse) |
2.1 bar @ 25℃ |
|
Biological Safety |
Endotoxins |
<0.25 EU/mL |
Extractables |
<40 mg/10inches |
|
Sterilizable |
Steam In-place |
121℃ 30min Differential Pressure<0.3 bar |
Autoclave |
121℃ 30min |
Typical Liquid Flow Rates
Ordering Information
CRNY |
Length |
Pore Size |
Adaptor |
Seal Material |
Core |
005=5" 010=10" 020=20" 030=30" 040=40" |
X02=0.20μm+0.20μm 020=0.20μm 045=0.45μm 065=0.65μm 100=1.0μm
|
0=DOE 1=222/Flat with SS insert 2=222/Flat 3=222/Fin 4=222/Fin with SS insert 5=226/Fin with SS insert 6=226/Fin 7=226/Flat 8=226/Flat with SS insert |
S=Silicone E=EPDM N=Nitrile F=FKM |
Blank=PP R=Reinforced PP S=316L Stainless Steel |